FLUKE 107 POCKET DIGITAL MULTIMETER

Fluke 107 Pocket Digital Multimeter

  • CAT III 600 V safety rating
  • Current and voltage measurements
  • Measures resistance and continuity to check for broken wires
  • Data hold and backlit display to keep you working safe and fast

 

Specifications of Fluke107 Pocket Digital Multimeter

Precision specifications

AC voltage

(40 Hz to 500 Hz)1

Range

Resolution

Accuracy

6.000 V

60.00 V

600.0 V

0.001 V

0.01 V

0.1 V

1.0 % + 3

DC voltage

6.000 V

60.00 V

600.0 V

0.001 V

0.01 V

0.1 V

0.5 % + 3

Exchange millivolts

600.0 mV

0.1 mV

3.0 % + 3

Diode test2

2.000 V

0.001 V

10 %

Resistance

(ohm)

400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitor3

50.00 nF

500.0 nF

5.000 μF

50.00 μF

500.0 μF

1000 μF

0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF

2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5

Frequency4 Hz

(10 Hz – 100 kHz)

50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

0.1 % + 3

Duty cycle4

1 % to 99 %

0.10 %

1 % typical case5

AC current

(40 Hz – 200 Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

DC

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

  1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.

  2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.

  3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).

  4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.

  5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.

Features

Overload protection

Input impedance (nominal value)

Common mode rejection ratio

Normal mode rejection ratio

AC voltage

600 V 1

>10 MΩ <100 pF 2

>60 dB at 50 Hz or 60 Hz at DC current

Exchange millivolts

600 mV

>1M, <100 pF

>80 dB at 50 Hz or 60 Hz

DC voltage

600 V 1

>10 MΩ <100 pF

>100 dB at 50 Hz or 60 Hz at DC current

>60 dB at 50 Hz or 60 Hz

  1. Up to 6 x 105 V Hz

  2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ.

General technical indicators

The highest voltage applied to any terminal and ground

600 V

Display (LCD)

6000 counts, updated three times per second

Type of battery

Two AAA batteries (NEDA 24A, IEC LR03)

Battery life

At least 200 hours

Temperature

Operating temperature

0 °C to 40 °C

Storage temperature

-30 °C to 60 °C

Relative humidity

Working humidity

No condensation below 10 °C

≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C

Working humidity, 40 MΩ range

≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C

Altitude

Working elevation

2000 m

Storage altitude

12,000 m

Temperature coefficient

0.1 X (specified accuracy) / °C (<18 °C or >28 °C)

Current input fuse protection

11A, 1000V fast-melting type, must use Fluke designated parts

Volume (height x width x length)

142 mm x 69 mm x 28 mm

Weight

200 g

Protection level

IEC 60529: IP 40

Safety

IEC 61010-1: 600 V CAT III, pollution degree 2

Electromagnetic environment

IEC 61326-1: Portable

Electromagnetic compatibility

Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1