FLUKE 87V INDUSTRIAL MULTIMETER

Fluke 87V Industrial Multimeter

  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture

Specifications Of Fluke 87V Industrial Multimeter

Specifications

Voltage DC

Maximum voltage

1000 V

Accuracy

±(0.05% + 1)

Maximum resolution

10 µV

Voltage AC

Maximum voltage

1000 V

Accuracy

±(0.7% + 2) True RMS

AC bandwidth

20 kHz with low pass filter; 3 dB @ 1 kHz

Maximum resolution

0.1 mV

Current DC

Maximum amps

10 A (20 A for 30 seconds maximum)

Amps accuracy

±(0.2% + 2)

Maximum resolution

0.01 µA

Current AC

Maximum amps

10 A (20 A for 30 seconds maximum)

Amps accuracy

±(1.0% + 2) True RMS

Maximum resolution

0.1 µA

Resistance

Maximum resistance

50 MΩ

Accuracy

±(0.2% + 1)

Maximum resolution

0.1 Ω

Capacitance

Maximum capacitance

9,999 µF

accuracy

±(1% + 2)

Maximum resolution

0.01 nF

Frequency

Maximum frequency

200 kHz

Accuracy

±(0.005% + 1)

Maximum resolution

0.01 Hz

Duty cycle

Maximum duty cycle

99.9%

Accuracy

±(0.2% per kHz + 0.1%)

Maximum resolution

0.1%

Temperature measurement

-200.0 °C to 1090 °C

-328.0 °F to 1994.0 °F

excluding probe

80 BK temperature probe

-40.0 °C to 260 °C

-40.0 °F to 500 °F, 2.2 °C or 2% whichever is greater

Conductance

Maximum conductance

60.00 nS

Accuracy

±(1.0% + 10)

Maximum resolution

0.01 nS

Diode

Range

3 V

Resolution

1 mV

Accuracy

±(2% + 1)

Duty cycle range

Accuracy

Within ±(0.2% per kHz + 0.1%)

Environmental Specifications

Operating temperature

–20 °C to + 55 °C

Storage temperature

–40 °C to + 60 °C

Humidity (without condensation)

0% – 90% (0 °C – 35 °C)

0% – 70% (35 °C – 55 °C)

Operating Altitude

2000 m

Safety Specifications

Overvoltage category

EN 61010–1 to 1000 V CAT III, 600V CAT IV

Agency approvals

CE, CSA, RCM

Mechanical and General Specifications

Size

201 x 98 x 52 mm (with holster)

Weight

355 g

624 g – with holster

Display

Digital

6000 counts updates 4/sec.

19,999 counts in high–resolution mode

Analog

32 segments, updates 40/sec

Frequency

19,999 counts, updates 3/sec at > 10 Hz

Warranty

Lifetime

Battery Life

Alkaline

~400 hours typical, without backlight

Shock

1 Meter drop per IEC 61010–1:2001

Vibration

Per MIL–PRF–28800 for a Class 2 instrument