The Fluke 319 Clamp Meter is an essential tool for electricians and technicians, offering high-precision measurement in a compact, portable design. It features a unique 40A low-current measurement with 0.01A resolution and 1.6% accuracy, making it ideal for diagnosing sensitive electrical systems. Its slim, lightweight clamps are perfect for confined spaces, while the large, backlit display ensures easy readability in dark environments. With advanced functions like starting current (inrush) measurement, current frequency measurement, and a screen hold function, the Fluke 319 provides comprehensive capabilities for a wide range of applications. The meter also includes a continuity beeper and an auto-off function to conserve battery life, making it a reliable and convenient tool backed by a one-year warranty.
General specifications |
|
Digital display |
6000 count resolution |
Low battery Indication |
Displays a signal when the batteries are below their required voltage |
Power source |
Three AAA IEC LR03 batteries |
Clamp opening size |
1.45 in (37 mm) |
Jaw diameter |
1.45 in (37 mm) |
Dimensions (L x W x H) |
9.21 in x 2.95 in x 1.37 in |
(234.0 mm x 75.0 mm x 34.8 mm) |
|
Weight |
Approximately 13.5 oz (384 g) (batteries included) |
Auto range |
Available in Ohms |
Safety |
CE |
EN/IEC 61010-1 and IEC 61010-2-032 |
|
Measurement Category: 600V CAT III |
|
317 Electrical specifications |
||
Current AC |
Range |
40.00 A, 600.0 A |
Resolution |
0.01 A, 0.1 A |
|
Accuracy |
1.6% ±6 digit (50-60 Hz) {40 A} |
|
2.5% ±8 digit (60-500 Hz) {40 A} |
||
1.5% ±5 digit (50-60 Hz) {600 A} |
||
2.5% ±5 digit (60-500 Hz) {600 A} |
||
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A |
|
AC response |
rms |
|
Current DC |
Range |
40.00 A, 600.0 A |
Resolution |
0.01 A, 0.1 A |
|
Accuracy |
1.6% ±6 digit (40 A) |
|
1.5% ±5 digit (600 A) |
||
Voltage AC |
Range |
600.0 V |
Resolution |
0.1 V |
|
Accuracy |
1.5% ±5 digit (20-500Hz) |
|
AC response |
rms |
|
Voltage DC |
Range |
600.0 V |
Resolution |
0.1 V |
|
Accuracy |
1% ±4 digit |
|
Resistance |
Range |
400.0 Ω, 4000 Ω |
Resolution |
0.1 Ω, 1 Ω |
|
Accuracy |
1% ±5 digit |
|
Continuity |
≤ 30 Ω |
|
Inrush |
Integration time |
N/A |
Frequency |
Range |
N/A |
Accuracy |
N/A |
|
Trigger Level |
N/A |
|
319 Electrical specifications |
||
Current AC |
Range |
40.00 A, 600.0 A, 1000 A |
Resolution |
0.01 A, 0.1 A, 1 A |
|
Accuracy |
1.6% ±6 digit (50-60 Hz) {40 A} |
|
2.5% ±8 digit (60-500 Hz) {40 A} |
||
1.5% ±5 digit (50-60 Hz) {600/1000 A} |
||
2.5% ±5 digit (60-500 Hz) {600/1000 A} |
||
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A |
|
AC response |
rms |
|
Current DC |
Range |
40.00 A, 600.0 A, 1000 A |
Resolution |
0.01 A, 0.1 A, 1 A |
|
Accuracy |
1.6% ±6 digit (40 A) |
|
1.5% ±5 digit (600/1000 A) |
||
Voltage AC |
Range |
600.0 V |
Resolution |
0.1 V |
|
Accuracy |
1.5% ±5 digit (20-500Hz) |
|
AC response |
rms |
|
Voltage DC |
Range |
600.0 V |
Resolution |
0.1 V |
|
Accuracy |
1% ±4 digit |
|
Resistance |
Range |
400.0 Ω |
4000 Ω |
||
Resolution |
0.1 Ω |
|
1 Ω |
||
Accuracy |
1% ±5 digit |
|
Continuity |
≤ 30 Ω |
|
Inrush |
Integration time |
100 ms |
Frequency |
Range |
5.0 – 500.0 Hz |
Accuracy |
0.5% ±5 digit |
|
Trigger Level |
10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A |
|
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
||
Environmental specifications |
|
Operating temperature |
14°F to 122°F (-10 °C to 50 °C) |
Storage temperature |
-40 °F to 140 °F (-40 °C to 60 °C) |
Operating humidity |
Non-condensing (< 50 °F) (< 10 °C) |
90% RH (50 °F to 86 °F) (10 °C to 30 °C) |
|
75% RH (86 °F to 104 °F) (30 °C to 40 °C) |
|
45% RH (104 °F to 122 °F) (40 °C to 50 °C) |
|
(Without condensation) |
|
Operating altitude |
1 mile (2000 meters) above mean sea level |
Storage altitude |
7 miles (12,000 meters) above mean sea level |
IP Rating |
IP40 |
Vibration requirements |
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop test requirements |
3 ft (1 m) drop test, six sides, oak floor |
EMI, RFI, EMC |
Instrument unspecified for use in EMC field ≥ 0.1 V/m |
Temperature coefficients |
0.1x (specified accuracy)/ °C |
(<64 °F or > 82° F) |
|
(<18 °C or > 28 °C) |
|