Specifications |
||
Accuracy Specifications |
||
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/resolution |
6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
|
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer. |
|
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9% + 1 |
|
Range/resolution |
40.00 MΩ / 0.01 MΩ |
|
Accuracy |
5% + 2 |
|
Diode test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
|
Capacitance |
Range/resolution |
1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
|
Range/resolution |
> 1000 μF |
|
Accuracy |
5% + 20% |
|
Lo-Z capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
|
AC amps True RMS(45 Hz to 500Hz) |
Range/resolution |
6.000 A / 0.001 A10.00 A / 0.01 A |
Accuracy |
1.5% + 320 A overload for 30-seconds max |
|
DC amps |
Range/resolution |
6.000 A / 0.001 A10.00 A / 0.01 A |
Accuracy |
1.0% + 320 A overload for 30-seconds max |
|
Hz (V or A input)2 |
Range/resolution |
99.99 Hz / 0.01 Hz999.9 Hz / 0.01 Hz9.999 kHz / 0.001 kHz50.00 kHz / 0.01 kHz |
Accuracy |
0.1% + 2 |
|
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉. |
General Specifications |
|
Maximum voltage between any terminal and earth ground |
600 V |
Safety |
IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600V |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10℃ to + 50℃ |
Storage temperature |
-40℃ to + 60℃ |
Battery type |
9 volt Alkaline, IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight |
550 g |
Warranty |
3 years |