FLUKE 115 FIELD TECHNICIANS DIGITAL MULTIMETER

Fluke 115 Field Technicians Digital Multimeter

  • Compact True-rms digital multimeter for field service
  • Includes: meter, holster, 4 mm PVC-Insulated test lead
  • Easy one-handed operation of the meter
  • Min/Max/Average to record signal fluctuations

 

Specifications of Fluke 115 Field Technicians Digital Multimeter

Specifications

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

AC millivolts1 True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of

500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω

6.000 kΩ / 0.001 kΩ

60.00 kΩ / 0.01 kΩ

600.0 kΩ / 0.1 kΩ

6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF

10.00 μF / 0.01 μF

100.0 μF / 0.1 μF

9999 μF / 1 μF

100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS

(45 Hz to 500Hz)

Range/resolution

6.000 A / 0.001 A

10.00 A / 0.01 A

Accuracy

1.5% + 3

20 A overload for 30-seconds max

DC amps

Range/resolution

6.000 A / 0.001 A

10.00 A / 0.01 A

Accuracy

1.0% + 3

20 A overload for 30-seconds max

Hz (V or A input)2

Range/resolution

99.99 Hz / 0.01 Hz

999.9 Hz / 0.01 Hz

9.999 kHz / 0.001 kHz

50.00 kHz / 0.01 kHz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.

2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.

2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.

2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.

General Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2

IEC 61010-2-033: CAT III 600V

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10℃ to + 50℃

Storage temperature

-40℃ to + 60℃

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty

3 years