FLUKE 117 ELECTRICIAN’S MULTIMETER WITH NON-CONTACT VOLTAGE

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

The Fluke 117 Electrician’s Multimeter is a compact, versatile True-RMS digital multimeter designed for electricians, technicians, and field professionals who demand accuracy, safety, and convenience in their work. With its robust functionality, this meter is ideal for troubleshooting electrical systems efficiently and reliably.

In addition, the Fluke 117 features integrated non-contact voltage (NCV) detection, allowing users to quickly and safely check for the presence of voltage without touching live wires, enhancing both safety and workflow. Moreover, the selectable low-impedance (LoZ) mode helps prevent false readings caused by “ghost voltages,” ensuring accurate and dependable measurements every time.

Furthermore, the multimeter comes complete with 4mm silicone test leads, a protective holster, and a user manual, providing electricians with everything needed for professional electrical testing in one convenient package. As a result, the Fluke 117 combines precision, safety, and portability, making it an indispensable tool for daily electrical troubleshooting and maintenance.

 

    • True-RMS measurement for accurate readings on both linear and non-linear loads.

    • Integrated non-contact voltage (NCV) detection for safe, touch-free voltage checks.

    • Selectable low-impedance (LoZ) mode to eliminate ghost voltages.

    • Compact and portable design for field and on-site work.

    • Complete with 4mm silicone test leads, holster, and manual.

    • Ideal for electricians, technicians, and maintenance professionals requiring a reliable, all-in-one multimeter.

Specifications of Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2

IEC 61010-2-033: CAT III 600V

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to +50°C

Storage temperature

-40°C to +60°C

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution

600.0 mV / 0.1 mV

Accuracy

±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy

±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution

600.0 V / 0.1 V

Accuracy

2.0% + 3 (DC, 45 Hz to 500 Hz)

4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution

600.0 mV / 0.1 mV

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution

6.000 V / 0.001 V

60.00 V / 0.01 V

600.0 V / 0.1 V

Accuracy

1.0% + 3 (DC, 45 Hz to 500 Hz)

2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution

600 Ω / 1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of

500 μs or longer.

Ohms

Range/resolution

600.0 Ω / 0.1 Ω

6.000 kΩ / 0.001 kΩ

60.00 kΩ / 0.01 kΩ

600.0 kΩ / 0.1 kΩ

6.000 MΩ / 0.001 MΩ

Accuracy

0.9% + 1

Range/resolution

40.00 MΩ / 0.01 MΩ

Accuracy

5% + 2

Diode test

Range/resolution

2.00 V / 0.001 V

Accuracy

0.9% + 2

Capacitance

Range/resolution

1000 nF / 1 nF

10.00 μF / 0.01 μF

100.0 μF / 0.1 μF

9999 μF / 1 μF

100 μF to 1000 μF

Accuracy

1.9% + 2

Range/resolution

> 1000 μF

Accuracy

5% + 20%

Lo-Z capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

AC amps True RMS (45 Hz to 500 Hz)

Range/resolution

6.000 A / 0.001 A

10.00 A / 0.01 A

Accuracy

1.5% + 3

20 A continuous overload for 30 seconds max

DC amps

Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy

1.0% + 3

20 A continuous overload for 30 seconds max

Hz (V or A input)²

Range/resolution

99.99 Hz / 0.01 Hz

999.9 Hz / 0.1 Hz

9.999 kHz / 0.001 Hz

50.00 kHz / 0.01 Hz

Accuracy

0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.

2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.

2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Mechanical and General Specifications

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty

3 years