KYORITSU 1061 DIGITAL MULTIMETER

Kyoritsu 1061 Digital Multimeter

  • 0.02% basic DC accuracy
  • Large display with 50,000 counts
  • Dual display for double indication for AC and DC, V and Hz, etc.
  • True RMS Measurements AC and AC+DC
  • Fast Peak Hold response time of 250µs

Safety design for industrial use

  • Complies with IEC 61010-1 CAT IV 600V, CAT III 1000V
  • Terminal shutter to prevent incorrect test leads’ insertion in current terminals
  • Very wide operating temperature range from -20 to 55ºC

Reliable support for data management

  • Large data internal memory
    KEW 1061: 1,000 data (logging), 100 data (manual)
  • Download data and Live Monitoring on a PC via the USB interface
    (Option for USB Communication set)
    * MAX 32,767 data can be transferred.

Specification Of Kyoritsu 1061 Digital Multimeter

Detection mode

Ture RMS

DC V

50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V

(Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V])

±0.02%rdg±2dgt (Basic accuracy)

AC V

500.00mV/5.0000/50.000/500.00/1000.0V

(Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V])

±0.7%rdg±30dgt (Basic accuracy)

DCV+ACV

5.0000/50.000/500.00/1000.0V

(Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V])

±1%rdg±10dgt (Basic accuracy)

DC A

500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

±0.2%rdg±5dgt (Basic accuracy)

AC A

500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

±1%rdg±20dgt (Basic accuracy)

DCA+ACA

500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A

±1.5%rdg±10dgt (Basic accuracy)

Ω

500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ

±0.1%rdg±2dgt (Basic accuracy)

Continuity buzzer

500.0Ω

(The buzzer turns on at resistances lower than 100±50Ω)

Diode test

2.4000V

±1%rdg±2dgt Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current)

Capacitance

5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF ±1%rdg±5dgt (Basic accuracy)

Frequency

2.000 to 9.999/9.00 to 99.99/90.0 to 999.9Hz/0.900 to 9.999/9.00 to 99.99kHz ±0.02%rdg±1dgt (Basic accuracy)

DUTY

10 to 90% ±1%rdg

Temperature

-200 to 1372ºC

±1%rdg±1.5ºC

-328 to 2501.6ºF

±1%rdg±2.0ºF (with the use of K-type Temperature probe)

Measurement functions

DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature

Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test

Other functions

Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG)

Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight

Applicable standards

IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2

IEC 61010-031, IEC 61326-1 (EMC)

Power source

R6 (1.5V)×4

(Auto power off: approx. 20 minutes)

Dimension

192(L)×90(W)×49(D) mm

Weight

Approx. 570g (including batteries and blank cover)

Accessories

7220A (Test leads)

8926 (Fuse [440mA/1000V])×1 (included)

8927 (Fuse [10A/1000V])×1 (included)

R6×4

Instruction manual

Blank cover

Optional accessories

7234 (Alligator clip)

8241 (USB Communication set)

8115 (AC/DC Clamp Sensor)

8121 (Load current Clamp Sensor)

8122 (Load current Clamp Sensor)

8123 (Load current Clamp Sensor)

8146 (Leakage & Load current Clamp Sensor)

8147 (Leakage & Load current Clamp Sensor)

8148 (Leakage & Load current Clamp Sensor)

7146 (Banana Ø4 adjuster plug)

8405 (Temperature probe)

8406 (Temperature probe)

8407 (Temperature probe)

8408 (Temperature probe)

9154 (Carring case)

Please download “DMM Application(software)” from here.