The Kyoritsu 6516BT Multi Function Installation Tester is a professional, all-in-one solution designed for electricians, inspection engineers, and electrical maintenance specialists. With its vibrant 3.5-inch color LCD display, it provides clear, real-time data, allowing faster, more accurate decision-making in the field. Furthermore, the intuitive display guides users through multiple functions effortlessly, therefore improving operational efficiency and reducing setup errors.
Moreover, the innovative Anti-Trip Technology enables LOOP L-PE testing without tripping RCDs, so it is suitable for both standard and no-neutral installations. In addition, the tester delivers comprehensive measurement capabilities, including LOOP, RCD, earth resistance, insulation resistance, continuity, phase rotation, voltage, SPD, and PAT testing, which ensures full compliance with electrical installation standards. Also, it supports multiple RCD types—AC, A, F, B, EV, and Variable—and provides single, auto, ramp, and contact voltage testing modes, thus offering versatile performance for a wide range of installation scenarios.
Additionally, Bluetooth® connectivity via the KEW CONNECT app and the on-screen HELP guides improve usability, so users can transfer data and follow proper testing procedures seamlessly. Finally, with IEC 61010-1 CAT IV 300V / CAT III 600V and IEC 61557 compliance, this tester guarantees professional-grade reliability, making it an essential tool for precise electrical diagnostics, certification, and installation verification.
Clear Display – 3.5-inch color LCD dot matrix for enhanced visibility and operation.
Anti-Trip Technology – Allows LOOP L-PE testing without tripping RCDs, even in no-neutral conditions.
High-Precision LOOP Test – Measures up to 2Ω with 0.001Ω resolution, and includes Zs Limit comparison to standards.
Advanced RCD Testing – Compatible with AC, A, F, B, EV, and Variable types; supports single, auto, ramp, and contact voltage tests.
Earth Resistance – 2-wire and 3-wire measurements with a full accessory set.
Insulation Testing – 100V, 250V, 500V, and 1000V ranges with automatic discharge for safety.
Continuity Testing – 200mA or 15mA selectable with optional buzzer for quick judgments.
Phase Rotation – Clear indication of sequence for 3-phase lines.
Voltage & Frequency – TRMS voltage measurement from 2V to 600V with mains frequency display.
HELP Function – On-screen connection diagrams for selected tests, therefore reducing setup errors.
SPD Testing – Verifies surge protection devices using varistors.
PAT Function – Tests insulation and protective conductor resistance for portable appliances.
Bluetooth® Connectivity – Wireless data transfer via KEW CONNECT app, allowing seamless data analysis.
Safety Rated – IEC 61010-1 CAT IV 300V / CAT III 600V and IEC 61557 compliance for professional electrical work.
Insulation resistance |
SPD (Varistor) |
||||||
---|---|---|---|---|---|---|---|
Test voltage |
100V | 250V | 500V | 1000V | Max.1000V | ||
Measuring ranges |
2.000/20.00/200.0MΩ (Auto-ranging) |
20.00/200.0/ 1000MΩ (Auto-ranging) |
20.00/200.0/ 2000MΩ (Auto-ranging) |
0 to 1049V (goes up by 1V) |
|||
Accuracy |
±2%rdg±6dgt (2.000/20.00MΩ) ±5%rdg±6dgt (200.0MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (1000MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (2000MΩ) |
±5%rdg±5dgt | |||
Rated current |
1.0 to 1.2mA @0.1MΩ |
1.0 to 1.2mA @0.25MΩ |
1.0 to 1.2mA @0.5MΩ |
1.0 to 1.2mA @1MΩ |
‐ | ||
Output short circuit current |
1.5mA max | ‐ | |||||
Loop impedance |
|||||||
Function |
LOOP ATT | LOOP HIGH | |||||
L-PE/L-N (3wire) |
L-PE (2wire) |
L-PE (0.01ΩRes) |
L-PE (0.001ΩRes) High test current (25A) |
L-N/L-L | |||
Rated voltage |
100 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
100 to 260V (50/60Hz) |
48 to 500V (50/60Hz) |
||
Impedance range |
20.00/200.0/2000Ω (Auto-ranging) |
20.00/200.0/2000Ω (Auto-ranging) |
2.000Ω | 20.00Ω | |||
Accuracy |
±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt | ||
Nominal test current at 0Ω external loop: Magnitude/ Duration at 230V |
L-N:6A/60ms N-PE:10mA |
L-PE:15mA | 20Ω: 6A/20ms 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms |
25A/20ms | 6A/20ms | ||
PSC/PFC |
|||||||
Range |
2000A/20kA (L-N(PSC)/L-PE(PFC)) |
2000A/20kA (PFC) |
2000A/20kA (PFC) |
2000A/50kA (PFC) |
2000A/20kA (PSC) |
||
Accuracy |
PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification | ||||||
RCD |
|||||||
Rated voltage | 100 to 260V(50/60Hz) | ||||||
Function | x1/2, x1,x5,Ramp,Auto,Uc | ||||||
6/10/30/100/300/500/1000mA/variable | |||||||
RCD type | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | ||
Trip current setting | x1/2, x1,Uc |
10/30/100/300/ 500/1000mA(G) 10/30/100/ 300/500(S) |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA (x1 only) |
|
x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | – | ||
Ramp | 10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA | ||
Accuracy | Trip current |
x1/2 | -8 to -2% | -10 to 0% | -10 to 0% | -10 to 0% | – |
x1 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | 0 to +10% | ||
x5 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | – | ||
Ramp | -4 to +4% | -10 to +10% | -10 to +10% | -10 to +10% | -10 to +10% | ||
Trip time |
x1/2 | 2000ms(G/S):±1%rdg±2ms | – | ||||
x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2㎳ | |||||
x5 | 410ms(G/S):±1%rdg±2ms | – | |||||
Continuity |
|||||||
Range | 20.00/200.0/2000Ω (Auto-ranging) | ||||||
Open circuit voltage(DC) | 7 to 14V | ||||||
Measuring current |
200mA | 200mA or more(2Ω or less) | |||||
15mA | 15mA±3mA(short-circuit) | ||||||
Accuracy | ±2%rdg±8dgt | ||||||
Volts |
|||||||
Range | 300.0/600V(Auto-ranging) | ||||||
Measuring ranges |
Volts | 2 to 600V | |||||
Frequency | 45 to 65Hz | ||||||
Accuracy | Volts | ±2%rdg±4dgt | |||||
Frequency | ±0.5%rdg±2dgt | ||||||
Phase Rotation |
|||||||
Rated voltage |
48 to 600V(45 to 65Hz) | ||||||
Remarks |
Remarks Correct phase sequence: are displayed “1.2.3” and mark Reversed phase sequence: are displayed “3.2.1” and mark |
||||||
Earth |
|||||||
Range |
20.00/200.0/2000Ω(Auto-ranging) | ||||||
Accuracy |
±2%rdg±0.08Ω(20.00Ω) ±2%rdg±3dgt(200.0/2000Ω) |
||||||
General |
|||||||
Applicable standards |
IEC 61010-1 CAT IV 300V / CAT III 600 V Pollution degree 2 IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10 IEC 60529(IP40), IEC 61326(EMC) |
||||||
Communication interface |
USB, Bluetooth® 5.0 | ||||||
Power source |
LR6 (AA) (1.5V) ×8 | ||||||
Communication interface |
USB | ||||||
Dimension / Weight |
136(L) × 235(W) × 114(D) mm / 1350g (including batteries) | ||||||
Accessories |
Mains test lead*1 7281 (Test leads with remote control switch) 7246 (Distribution board test lead) 7228A (Earth resistance test leads) 8041 (Auxiliary earth spikes[2 spikes/1 set]) 9084 (Soft case) 9142 (Carrying case) 9151 (Shoulder strap) 9199 (Shoulder pad) LR6(AA) × 8 Instruction manual Calibration certificate |
||||||
Optional Accessories |
8212-USB (USB adapter) 8259 (Adapter for measurement terminal) 7272 (Precision measurement cord set) 8017A (Extension prod long) 8602 (EVSE ADAPETER) |
Please download “KEW Report(software)” from here.